Diesel Generator Sets

SHARE

Diesel Generator Sets C7.1 (60 Hz)

120 - 175 ekW Diesel Generator Set

Producing reliable power from 120 to 175 ekW at 60 Hz, our C7.1 diesel generator sets designed to ISO 8528-5 transient response requirement. All C7.1 generator sets are available with a choice of emissions levels.

Minimum Rating

120 ekW

Maximum Rating

175 ekW

Emissions/Fuel Strategy

Non Regulated

FEATURES AT A GLANCE

  • Cat Generator Set Package
  • Cat Diesel Engine
  • R-Frame Alternator
  • GCCP 1.3 Control Panel
  • Cooling System
  • Certifications
  • One Safe Source
  • World Wide Product Support
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

PRODUCT SPECIFICATIONS FOR Diesel Generator Sets C7.1 (60 Hz)

Generator Set Specifications

Minimum Rating 120 ekW
Maximum Rating 175 ekW
Emissions/Fuel Strategy Non Regulated
Voltage 208 to 480 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby, Prime
Minimum Rating
120 ekW
Maximum Rating
175 ekW
Emissions/Fuel Strategy
Non Regulated
Voltage
208 to 480 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model C7.1 I-6, 4-Cycle Diesel
Bore 105 mm
Stroke 135 mm
Displacement 7.01 B
Compression Ratio 16.5:1
Aspiration Turbocharged, Air to Air Aftercooled
Fuel System Common Rail
Governor Type ADEM™A4
Engine Model
C7.1 I-6, 4-Cycle Diesel
Bore
105 mm
Stroke
135 mm
Displacement
7.01 B
Compression Ratio
16.5:1
Aspiration
Turbocharged, Air to Air Aftercooled
Fuel System
Common Rail
Governor Type
ADEM™A4

Generator Set Dimensions

Length - Maximum 2500 mm
Width - Maximum 1320 mm
Height - Maximum 1626 mm
Length - Maximum
2500 mm
Width - Maximum
1320 mm
Height - Maximum
1626 mm

SEE HOW CAT Diesel Generator Sets C7.1 (60 Hz) COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Diesel Generator Sets

C1.5 (60 Hz)

Minimum Rating-12 ekW

Maximum Rating-13.2 ekW

Emissions/Fuel Strategy-R96/EUIIIa Equivalent


explore

Diesel Generator Sets

3516B (50 Hz) India Market Only

Minimum Rating-2000 kVA

Maximum Rating-2250 kVA

Emissions/Fuel Strategy-Low Fuel Consumption


explore

Diesel Generator Sets

C18 (60 Hz)

Minimum Rating-500 ekW

Maximum Rating-600 ekW

Emissions/Fuel Strategy-Low Fuel Consumption


explore

Diesel Generator Sets

C1.5 (60 Hz)

Minimum Rating-12 ekW

Maximum Rating-13.2 ekW

Emissions/Fuel Strategy-R96/EUIIIa Equivalent


explore

Diesel Generator Sets

3516B (50 Hz) India Market Only

Minimum Rating-2000 kVA

Maximum Rating-2250 kVA

Emissions/Fuel Strategy-Low Fuel Consumption


explore

Diesel Generator Sets

C18 (60 Hz)

Minimum Rating-500 ekW

Maximum Rating-600 ekW

Emissions/Fuel Strategy-Low Fuel Consumption


explore

compare

To quote, please fill out the form below