Diesel Generator Sets

SHARE

Diesel Generator Sets D250 GC

250 ekW Diesel Generator Set

Producing reliable power of 250 ekW at 60 Hz, our D250 GC diesel generator set are designed to ISO 8528-5 transient response requirements. The D250 GC generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards.

Minimum Rating

250 ekW

Maximum Rating

250 ekW

Emissions/Fuel Strategy

EPA Stationary Emergency

FEATURES AT A GLANCE

  • Cat Generator Set Package
  • Cat Diesel Engine
  • M-Frame Alternator
  • GCCP 1.2 Control Panel
  • Cooling System
  • Certifications
  • One Safe Source
  • World Wide Product Support
  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

PRODUCT SPECIFICATIONS FOR Diesel Generator Sets D250 GC

Generator Set Specifications

Minimum Rating 250 ekW
Maximum Rating 250 ekW
Emissions/Fuel Strategy EPA Stationary Emergency
Voltage 208 to 600 Volts
Frequency 60 Hz
Speed 1800 rpm
Duty Cycle Standby
Minimum Rating
250 ekW
Maximum Rating
250 ekW
Emissions/Fuel Strategy
EPA Stationary Emergency
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby

Engine Specifications

Engine Model Cat® C9 In-line 6, 4-cycle Diesel
Bore 112 mm
Stroke 149 mm
Displacement 8.8 l
Compression Ratio 16.3:1
Aspiration Turbocharged Air-to-Air Aftercooled
Fuel System HEUI
Governor Type Adem™A4
Engine Model
Cat® C9 In-line 6, 4-cycle Diesel
Bore
112 mm
Stroke
149 mm
Displacement
8.8 l
Compression Ratio
16.3:1
Aspiration
Turbocharged Air-to-Air Aftercooled
Fuel System
HEUI
Governor Type
Adem™A4

Generator Set Dimensions

Length - Maximum 3950 mm
Width - Minimum 1430 mm
Width - Maximum 1440 mm
Height - Minimum 1706 mm
Height - Maximum 2202 mm
Dry Weight - Genset (minimum) 2415 kg
Dry Weight - Genset (maximum) 3055 kg
Length - Maximum
3950 mm
Width - Minimum
1430 mm
Width - Maximum
1440 mm
Height - Minimum
1706 mm
Height - Maximum
2202 mm
Dry Weight - Genset (minimum)
2415 kg
Dry Weight - Genset (maximum)
3055 kg

SEE HOW CAT Diesel Generator Sets D250 GC COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Diesel Generator Sets

DE200 GC (60 Hz)

Minimum Rating-175 ekW

Maximum Rating-175 ekW

Emissions/Fuel Strategy-Non Regulated


explore

Diesel Generator Sets

C13 (60 Hz)

Minimum Rating-320 ekW

Maximum Rating-400 ekW

Emissions/Fuel Strategy-EPA Stationary Emerg Use


explore

Diesel Generator Sets

3412C (50 Hz)

Minimum Rating-680 kVA

Maximum Rating-900 kVA

Emissions/Fuel Strategy-Low Fuel Consumption


explore

Diesel Generator Sets

DE200 GC (60 Hz)

Minimum Rating-175 ekW

Maximum Rating-175 ekW

Emissions/Fuel Strategy-Non Regulated


explore

Diesel Generator Sets

C13 (60 Hz)

Minimum Rating-320 ekW

Maximum Rating-400 ekW

Emissions/Fuel Strategy-EPA Stationary Emerg Use


explore

Diesel Generator Sets

3412C (50 Hz)

Minimum Rating-680 kVA

Maximum Rating-900 kVA

Emissions/Fuel Strategy-Low Fuel Consumption


explore

compare

To quote, please fill out the form below

NAME*

TELEPHONE*

E-MAIL

COMPANY

SELECT SERVICE BRANCH

VERIFICATION CODE

-->