Diesel Generator Sets

SHARE

Diesel Generator Sets C32 (50 Hz) India Market Only

1010 - 1250 kVA Diesel Generator Set

Producing reliable power from 1010 kVA to 1250 kVA at 50 Hz, our C32 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 per cent rated load in one step. Generator sets offer a low fuel consumption system.

Minimum Rating

1010 kVA

Maximum Rating

1250 kVA

Emissions/Fuel Strategy

Low Fuel Consumption

FEATURES AT A GLANCE

  • World Wide Product Support
  • Cat Diesel Engine
  • SR5 Alternator
  • EMCP 4 Control Panel
  • Cooling System
  • Certifications
  • One Safe Source
  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

PRODUCT SPECIFICATIONS FOR Diesel Generator Sets C32 (50 Hz) India Market Only

Generator Set Specifications

Minimum Rating 1010 kVA
Maximum Rating 1250 kVA
Emissions/Fuel Strategy Low Fuel Consumption
Voltage 415 Vots
Frequency 50 Hz
Speed 1500 rpm
Duty Cycle Standby, Prime
Minimum Rating
1010 kVA
Maximum Rating
1250 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Voltage
415 Vots
Frequency
50 Hz
Speed
1500 rpm
Duty Cycle
Standby, Prime

Engine Specifications

Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore 145 mm
Stroke 162 mm
Displacement 32.1 l
Compression Ratio 15.0:1
Aspiration TA
Fuel System MEUI
Governor Type Adem™A4
Engine Model
C32 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore
145 mm
Stroke
162 mm
Displacement
32.1 l
Compression Ratio
15.0:1
Aspiration
TA
Fuel System
MEUI
Governor Type
Adem™A4

SEE HOW CAT Diesel Generator Sets C32 (50 Hz) India Market Only COMPARES AGAINST FREQUENTLY COMPARED PRODUCTS.

Diesel Generator Sets

DE88 GC (60 Hz)

Minimum Rating-80 ekW

Maximum Rating-80 ekW

Emissions/Fuel Strategy-Non Regulated


explore

Diesel Generator Sets

3516B DGB™ (60 Hz)

Minimum Rating-1640 ekW

Maximum Rating-1825 ekW

Emissions/Fuel Strategy-Low Fuel Consumption


explore

Diesel Generator Sets

DE220 GC (50 Hz)

Minimum Rating-217 kVA

Maximum Rating-217 kVA

Emissions/Fuel Strategy-Non Regulated


explore

Diesel Generator Sets

DE88 GC (60 Hz)

Minimum Rating-80 ekW

Maximum Rating-80 ekW

Emissions/Fuel Strategy-Non Regulated


explore

Diesel Generator Sets

3516B DGB™ (60 Hz)

Minimum Rating-1640 ekW

Maximum Rating-1825 ekW

Emissions/Fuel Strategy-Low Fuel Consumption


explore

Diesel Generator Sets

DE220 GC (50 Hz)

Minimum Rating-217 kVA

Maximum Rating-217 kVA

Emissions/Fuel Strategy-Non Regulated


explore

compare

To quote, please fill out the form below

NAME*

TELEPHONE*

E-MAIL

COMPANY

SELECT SERVICE BRANCH

VERIFICATION CODE

-->